龙岩市MedAccred _AC8121电子电缆和线束组件的审核标准 (94)

40.3.21 C- Is there evidence that pull test samples passed the requirement minimum pull forces, in accordance with procedures / customer requirements?YES/NO

40.3.22 C- Are samples used for tensile testing prevented from being used in deliverable product?YES/NO

40.3.23 C- If required, are pull test break categories being recorded for pull test samples?YES/NO/NA

40.3.24 C- If required, are the minimum pull force requirements for 18 AWG nickel-plated wire in accordance with customer requirements?YES/NO/NA

40.3.25 C- Are pull tests performed on terminals with multiple wires tested correctly and to the proper minimum forces, in accordance with procedures / customer requirements?YES/NO

40.3.26 C- Is there evidence of personnel training to the tensile testing requirements in accordance with procedures / customer requirements, including tool use?YES/NO

40.3.27 C- Is there evidence of compliance to contact retention testing requirements in accordance with the procedure / customer requirements?YES/NO

40.3.28 C- Is there evidence of personnel training to the contact retention testing requirements in accordance with procedures / customer requirements, including tool use when tool is used?YES/NO.

40.3.29 C- Is the procedure for the preparation and production of crimp samples for testing, for identification, traceability, and control, being followed?YES/NO/NA

40.3.30 C- If crimp height testing is required by customer, is there evidence that crimp heights (and widths, if required) meet the defined requirements in accordance with procedures / customer requirements?YES/NO/NA