29.21 C- If used, is each wire inspected for acceptability, when multiple wires are attached to a single terminal when manufacturing crimp splices?YES/NO/NA

29.22 C- If used, does the Circular Mil Area (CMA) for wires in a crimp splice comply with the CMA requirements of the terminal?YES/NO/NA

29.23 C- Is there evidence that operators performing solder splices are trained to the documented general hand soldering requirements of IPC/WHMA- A-620 / customer requirements / procedures?YES/NO/NA

29.24C- Is there evidence that operators performing crimp splices are trained to the documented general crimping requirements of IPC/WHMA-A-620 / customer requirements / procedures? YES/NO/NA

30. CONNECTORIZATION

30.1Connector Hardware Mounting

30.1.1P- Is there a procedure to ensure maximum connector pin contact of mating connectors when installing connectors?YES/NO

30.1.2 P- Is there a procedure for acceptance criteria of installed connector hardware?YES/NO

30.1.3C- Is there evidence that maximum connector pin contact has been achieved when assembling connectors?YES/NO

30.1.4C- Is there evidence that hardware installation for connectors is being performed in accordance with procedures?YES/NO

30.1.5C- Is the procedure for acceptance criteria of installed connector hardware available and being followed?YES/NO