阿勒泰市MedAccred _AC8102热处理基准审核标准【37】
18.2.4 Step One – Time YES/NO
18.2.4.1 (EC) Step One – Time
REQUIREMENT |
SHOP PAPER REQUIREMENT |
ACTUAL |
|
Atmosphere |
(EC) |
(EC) |
(EC) |
Time and Tolerance |
(EC) |
(EC) |
(EC) |
Time loaded into furnace |
|||
Time start of soak |
(EC) |
||
Time end of soak |
(EC) |
||
Media for Cooling |
(EC) |
(EC) |
(EC) |
Cooling Rate (Excluding Quench) |
(EC) |
(EC) |
(EC) |
18.3 Thermal Treatment Step Two SECTION NA
18.3.1 Thermal Treatment Step Two Temper SECTION NA
18.3.1.1 Step Two Temper
18.3.1.1.1 Furnace used:
18.3.1.1.2 Date part(s) processed:
18.3.1.2 Does the furnace possess the control and recording instrumentation required by the governing specification for this heat treatment? YES/NO
18.3.1.3 (EC) Step Two Temper – Temperature
REQUIREMEN T |
SHOP PAPER REQUIREMENT |
SET TEMPERATUR E |
ACTUAL TEMPERATURES |
||
Temperature |
(EC) |
(EC) |
(EC) |
||
Check if used |
|||||
Control |
(EC) |
||||
Recorder |
(EC) |
||||
High/Low - Type A or C Instrumentation |
(EC) |
||||
Load Thermocouples |
(EC) |
18.3.1.4 (EC) Step Two Temper – Time
REQUIREMENT |
SHOP PAPER REQUIREMENT |
ACTUAL |
|
Atmosphere |
(EC) |
(EC) |
(EC) |
Time and Tolerance |
(EC) |
(EC) |
(EC) |
Time loaded into furnace |
|||
Time start of soak |
(EC) |
||
Time end of soak |
(EC) |
||
Media for Cooling |
(EC) |
(EC) |
(EC) |
Cooling Rate (Excluding Quench) |
(EC) |
(EC) |
(EC) |